Specifications:
- Easy to assemble with double flange
- Cable material according to drinking water regulations (VDE/ACS/KTW approved)
- SAND FIGHTER™ SiC seal system for high performance in sand
- High efficiency electrical dsign for low operation cost
- All motors prefilled and 100% tested
- Maximum storage temperature -15 °C to +60 °C
- Designed for retrofitable Pt100 sensor
- Non-contaminating FES93 filled design
- Standard Water Well construction have cast iron end frames epoxy coated with 316SS stator shell
Technical Specifications:
- 185 to 400 kW
- 12 inch flange
- Protection: IP68
- Starts per hour: max. 5
- Installation position: vertical/horizontal
- Motor lead in 6 metre length (KTW approved)
- Standard voltage: 380-415 V/50Hz, 460 V/60Hz
- Voltage tolerance 50 Hz: -10% / +6% UN = (380 -10%) – (415V +6%)
- Voltage tolerance 60Hz: ±10% Un
- Motor protection: Select thermal overloads according to EN 61947-4-1, trip class 10 or 10A, trip time <10s at 5 x IN
- 30°C ambient temperature with a min. cooling flow of: v = 0.5 m/s
Options:
- 80 kN thrust load
- Other voltages:1,000 V, 2,300 V and 3,300 V 50 Hz DOL motors for high voltages are available for Standard, 316SS and 904L constructions.
- Wye/Star Delta start (pos. of cables 90°)
- Pt100 temperature sensor (sold separately)
- Special lead lngths upon request